Reference / Motor Efficiency
Quick reference · Grade G

Motor Minimum Efficiency (DOE)

The nominal full-load efficiency that general-purpose motors sold in the US must meet, by horsepower, pole count and enclosure.

From June 1, 2016 — Table 5 percent — enclosed = TEFC, open = ODP

hpkW2-pole enclosed2-pole open4-pole enclosed4-pole open6-pole enclosed6-pole open8-pole enclosed8-pole open
10.7577.077.085.585.582.582.575.575.5
1.51.184.084.086.586.587.586.578.577.0
21.585.585.586.586.588.587.584.086.5
32.286.585.589.589.589.588.585.587.5
53.788.586.589.589.589.589.586.588.5
7.55.589.588.591.791.091.090.286.589.5
107.590.289.591.791.791.091.789.590.2
151191.090.292.493.091.791.789.590.2
201591.091.093.093.091.792.490.291.0
2518.591.791.793.693.693.093.090.291.0
302291.791.793.694.193.093.691.791.7
403092.492.494.194.194.194.191.791.7
503793.093.094.594.594.194.192.492.4
604593.693.695.095.094.594.592.493.0
755593.693.695.495.094.594.593.694.1
1007594.193.695.495.495.095.093.694.1
1259095.094.195.495.495.095.094.194.1
15011095.094.195.895.895.895.494.194.1
20015095.495.096.295.895.895.494.594.1
25018695.895.096.295.895.895.895.095.0
30022495.895.496.295.895.895.8——
35026195.895.496.295.895.895.8——
40029895.895.896.295.8————
45033695.896.296.296.2————
50037395.896.296.296.2————

From June 1, 2027 — Table 8 percent — bold = higher than 2016; excludes fire pump and air-over motors

hpkW2-pole enclosed2-pole open4-pole enclosed4-pole open6-pole enclosed6-pole open8-pole enclosed8-pole open
10.7577.077.085.585.582.582.575.575.5
1.51.184.084.086.586.587.586.578.577.0
21.585.585.586.586.588.587.584.086.5
32.286.585.589.589.589.588.585.587.5
53.788.586.589.589.589.589.586.588.5
7.55.589.588.591.791.091.090.286.589.5
107.590.289.591.791.791.091.789.590.2
151191.090.292.493.091.791.789.590.2
201591.091.093.093.091.792.490.291.0
2518.591.791.793.693.693.093.090.291.0
302291.791.793.694.193.093.691.791.7
403092.492.494.194.194.194.191.791.7
503793.093.094.594.594.194.192.492.4
604593.693.695.095.094.594.592.493.0
755593.693.695.495.094.594.593.694.1
1007595.094.596.296.295.895.894.595.0
1259095.494.596.296.295.895.895.095.0
15011095.494.596.296.296.295.895.095.0
20015095.895.496.596.296.295.895.495.0
25018696.295.496.596.296.296.295.495.4
30022495.895.496.295.895.895.8——
35026195.895.496.295.895.895.8——
40029895.895.896.295.8————
45033695.896.296.296.2————
50037395.896.296.296.2————
55041095.896.296.296.2————
60044795.896.296.296.2————
65048595.896.296.296.2————
70052295.896.296.296.2————
75055995.896.296.296.2————

Sources: 10 CFR 431.25(h), Table 5 — NEMA Design A and B and IEC Design N general-purpose motors, compliance from June 1, 2016; 10 CFR 431.25(n), Table 8 — NEMA Design A and B and IEC Design N motors (excluding fire pump and air-over motors), compliance from June 1, 2027. © RokBench.

Screening toolfor licensed professionals. Not an engineering service. See Disclaimer.