Reference / Motor Efficiency
Quick reference · Grade G
Motor Minimum Efficiency (DOE)
The nominal full-load efficiency that general-purpose motors sold in the US must meet, by horsepower, pole count and enclosure.
From June 1, 2016 — Table 5 percent — enclosed = TEFC, open = ODP
| hp | kW | 2-pole enclosed | 2-pole open | 4-pole enclosed | 4-pole open | 6-pole enclosed | 6-pole open | 8-pole enclosed | 8-pole open |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 0.75 | 77.0 | 77.0 | 85.5 | 85.5 | 82.5 | 82.5 | 75.5 | 75.5 |
| 1.5 | 1.1 | 84.0 | 84.0 | 86.5 | 86.5 | 87.5 | 86.5 | 78.5 | 77.0 |
| 2 | 1.5 | 85.5 | 85.5 | 86.5 | 86.5 | 88.5 | 87.5 | 84.0 | 86.5 |
| 3 | 2.2 | 86.5 | 85.5 | 89.5 | 89.5 | 89.5 | 88.5 | 85.5 | 87.5 |
| 5 | 3.7 | 88.5 | 86.5 | 89.5 | 89.5 | 89.5 | 89.5 | 86.5 | 88.5 |
| 7.5 | 5.5 | 89.5 | 88.5 | 91.7 | 91.0 | 91.0 | 90.2 | 86.5 | 89.5 |
| 10 | 7.5 | 90.2 | 89.5 | 91.7 | 91.7 | 91.0 | 91.7 | 89.5 | 90.2 |
| 15 | 11 | 91.0 | 90.2 | 92.4 | 93.0 | 91.7 | 91.7 | 89.5 | 90.2 |
| 20 | 15 | 91.0 | 91.0 | 93.0 | 93.0 | 91.7 | 92.4 | 90.2 | 91.0 |
| 25 | 18.5 | 91.7 | 91.7 | 93.6 | 93.6 | 93.0 | 93.0 | 90.2 | 91.0 |
| 30 | 22 | 91.7 | 91.7 | 93.6 | 94.1 | 93.0 | 93.6 | 91.7 | 91.7 |
| 40 | 30 | 92.4 | 92.4 | 94.1 | 94.1 | 94.1 | 94.1 | 91.7 | 91.7 |
| 50 | 37 | 93.0 | 93.0 | 94.5 | 94.5 | 94.1 | 94.1 | 92.4 | 92.4 |
| 60 | 45 | 93.6 | 93.6 | 95.0 | 95.0 | 94.5 | 94.5 | 92.4 | 93.0 |
| 75 | 55 | 93.6 | 93.6 | 95.4 | 95.0 | 94.5 | 94.5 | 93.6 | 94.1 |
| 100 | 75 | 94.1 | 93.6 | 95.4 | 95.4 | 95.0 | 95.0 | 93.6 | 94.1 |
| 125 | 90 | 95.0 | 94.1 | 95.4 | 95.4 | 95.0 | 95.0 | 94.1 | 94.1 |
| 150 | 110 | 95.0 | 94.1 | 95.8 | 95.8 | 95.8 | 95.4 | 94.1 | 94.1 |
| 200 | 150 | 95.4 | 95.0 | 96.2 | 95.8 | 95.8 | 95.4 | 94.5 | 94.1 |
| 250 | 186 | 95.8 | 95.0 | 96.2 | 95.8 | 95.8 | 95.8 | 95.0 | 95.0 |
| 300 | 224 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 | — | — |
| 350 | 261 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 | — | — |
| 400 | 298 | 95.8 | 95.8 | 96.2 | 95.8 | — | — | — | — |
| 450 | 336 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
| 500 | 373 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
From June 1, 2027 — Table 8 percent — bold = higher than 2016; excludes fire pump and air-over motors
| hp | kW | 2-pole enclosed | 2-pole open | 4-pole enclosed | 4-pole open | 6-pole enclosed | 6-pole open | 8-pole enclosed | 8-pole open |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 0.75 | 77.0 | 77.0 | 85.5 | 85.5 | 82.5 | 82.5 | 75.5 | 75.5 |
| 1.5 | 1.1 | 84.0 | 84.0 | 86.5 | 86.5 | 87.5 | 86.5 | 78.5 | 77.0 |
| 2 | 1.5 | 85.5 | 85.5 | 86.5 | 86.5 | 88.5 | 87.5 | 84.0 | 86.5 |
| 3 | 2.2 | 86.5 | 85.5 | 89.5 | 89.5 | 89.5 | 88.5 | 85.5 | 87.5 |
| 5 | 3.7 | 88.5 | 86.5 | 89.5 | 89.5 | 89.5 | 89.5 | 86.5 | 88.5 |
| 7.5 | 5.5 | 89.5 | 88.5 | 91.7 | 91.0 | 91.0 | 90.2 | 86.5 | 89.5 |
| 10 | 7.5 | 90.2 | 89.5 | 91.7 | 91.7 | 91.0 | 91.7 | 89.5 | 90.2 |
| 15 | 11 | 91.0 | 90.2 | 92.4 | 93.0 | 91.7 | 91.7 | 89.5 | 90.2 |
| 20 | 15 | 91.0 | 91.0 | 93.0 | 93.0 | 91.7 | 92.4 | 90.2 | 91.0 |
| 25 | 18.5 | 91.7 | 91.7 | 93.6 | 93.6 | 93.0 | 93.0 | 90.2 | 91.0 |
| 30 | 22 | 91.7 | 91.7 | 93.6 | 94.1 | 93.0 | 93.6 | 91.7 | 91.7 |
| 40 | 30 | 92.4 | 92.4 | 94.1 | 94.1 | 94.1 | 94.1 | 91.7 | 91.7 |
| 50 | 37 | 93.0 | 93.0 | 94.5 | 94.5 | 94.1 | 94.1 | 92.4 | 92.4 |
| 60 | 45 | 93.6 | 93.6 | 95.0 | 95.0 | 94.5 | 94.5 | 92.4 | 93.0 |
| 75 | 55 | 93.6 | 93.6 | 95.4 | 95.0 | 94.5 | 94.5 | 93.6 | 94.1 |
| 100 | 75 | 95.0 | 94.5 | 96.2 | 96.2 | 95.8 | 95.8 | 94.5 | 95.0 |
| 125 | 90 | 95.4 | 94.5 | 96.2 | 96.2 | 95.8 | 95.8 | 95.0 | 95.0 |
| 150 | 110 | 95.4 | 94.5 | 96.2 | 96.2 | 96.2 | 95.8 | 95.0 | 95.0 |
| 200 | 150 | 95.8 | 95.4 | 96.5 | 96.2 | 96.2 | 95.8 | 95.4 | 95.0 |
| 250 | 186 | 96.2 | 95.4 | 96.5 | 96.2 | 96.2 | 96.2 | 95.4 | 95.4 |
| 300 | 224 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 | — | — |
| 350 | 261 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 | — | — |
| 400 | 298 | 95.8 | 95.8 | 96.2 | 95.8 | — | — | — | — |
| 450 | 336 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
| 500 | 373 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
| 550 | 410 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
| 600 | 447 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
| 650 | 485 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
| 700 | 522 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
| 750 | 559 | 95.8 | 96.2 | 96.2 | 96.2 | — | — | — | — |
Sources: 10 CFR 431.25(h), Table 5 — NEMA Design A and B and IEC Design N general-purpose motors, compliance from June 1, 2016; 10 CFR 431.25(n), Table 8 — NEMA Design A and B and IEC Design N motors (excluding fire pump and air-over motors), compliance from June 1, 2027. © RokBench.