Every external dataset RokBench computes with, with its licence, data date, what it feeds and when we last checked it. Standards (NEC, NFPA, IEEE, NEMA, IES, ASHRAE) are cited by clause and never reproduced; their values are your inputs.

Public datasets in use

● primary (the publisher's own regulation text, dataset or manual). Values are parsed from the original tables and cross-checked cell by cell; see Validation for the worked examples.

DatasetWhat it isLicenceData dateFeedsLast checked
● DOE 10 CFR 431 Subpart BMinimum full-load efficiency of general and special purpose motors, by HP, poles and enclosure (regulation text, Table 5)US federal regulation text, public domain (17 U.S.C. §105)2016 and 2027 levelsMotor efficiency defaults in load and generator tools; Reference table2026-09-28
● DOE 10 CFR 431 Subpart KMinimum efficiency of liquid-immersed and dry-type distribution transformers by kVA at the specified loadUS federal regulation text, public domain2016 and 2029 levelsTransformer loss defaults in electrical-room heat; Reference table2026-09-28
● DOE 10 CFR 431.97Floor-mounted computer-room air conditioner minimum NSenCOP (Table 13)US federal regulation text, public domaincurrent tableElectrical-room cooling power default2026-09-29
● OSHA 29 CFR 1910.303 and 1910.269Working-space depths by voltage and condition; minimum approach distances for power workUS federal regulation text, public domaincurrent textReference tables S-1, S-2 and approach distances2026-09-28
● UFC 3-540-01 Engine-Driven Generator SystemsGenerator criteria: non-linear load share and subtransient reactance, fire-pump starting dip, minimum loading (wet stacking)US DoD Unified Facilities Criteria, public distributionChange 3, 2023Generator warnings and fire-pump sizing2026-09-28
● USACE TM 5-698-5Survey of failure rates and repair times for power, generation and HVAC equipment (PREP database)US Army Corps of Engineers technical manual, public2006Default failure and repair rates in the contingency study (packages/engine contingency/rates.json)2026-10-03
● NASA POWER climate normalsMonthly climate averages on a 0.5° grid: temperatures and tilted-surface irradianceNASA Langley, public, commercial use allowed, attribution requested2001–2020 normalsSolar plane-of-array irradiance and cable ambient temperature (/api/v1/site/climate; queried only when you press the button)2026-09-29
● NREL PVWatts (National Laboratory of the Rockies)Site-specific photovoltaic yield modelUS DOE national laboratory API, free keyliveSolar yield comparison and POA fill (/api/v1/site/pvwatts)2026-10-03
● EPA eGRIDSubregion generation and non-baseload CO₂ emission factors; Power Profiler ZIP-to-subregion tableUS EPA, publiceGRID2023 rev2Solar CO₂ reduction estimate by ZIP2026-09-29
● NASA LIS/OTD HRFC lightning climatologyGlobal 0.5° annual flash density (total flashes, cloud flashes included)NASA GHRC, publicHRFC V2.3.2015Lightning ground-flash density estimate (Ng = Nt/3 by default); no data beyond 75° latitude2026-10-03
● NIST SP 811SI unit definitions and conversion factorsUS NIST, public2008 editionUnits reference page2026-09-28

What is input, what is computed, what is referenced

Input: your model and the standard-table values you enter (breaker test X/R, motor multipliers, cable ampacity tables). Computed: everything the engine derives from inputs by the formulas on the Methods pages, with the formula and figure shown. Referenced: the public datasets above, used as defaults you can override, each labelled with its source next to the value. Nothing on the site is a sealed deliverable or a design decision.

Corrections

If a value, a formula or a dataset date here is wrong, write to [email protected] with the page, the value you saw and the source that supports the change. Accepted corrections are logged in the Changelog; we do not silently edit published values. See also the Disclaimer and About.

Screening toolfor licensed professionals. Not an engineering service. See Disclaimer.